Advanced Search

Journal Navigation

Journal Home

Subscriptions

Archive

Contact Us

Table of Contents

CiteULike is a free service for managing and discovering scholarly references - click here to get started.

Sign In to gain access to subscriptions and/or personal tools.
Perfusion
This Article
Right arrow Full Text (PDF)
Right arrow References
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Saved Citations
Right arrow Download to citation manager
Right arrowRequest Permissions
Right arrow Request Reprints
Right arrow Add to My Marked Citations
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Right arrow Citing Articles via Scopus
Google Scholar
Right arrow Articles by De Somer, F.
Right arrow Articles by Van Nooten, G.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by De Somer, F.
Right arrow Articles by Van Nooten, G.
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati   Add to Twitter  
What's this?

D-901 neonatal oxygenator: a new perspective

F. De Somer

Department of Perfusion, University Hospital Gent

K. François

Department of Cardiac Surgery, University Hospital Gent

L. Foubert

Department of Anaesthesia, University Hospital Gent

Y. Deryck

Department of Anaesthesia, University Hospital Gent

D. De Smet

Department of Perfusion University Hospital Gent

M. Vanackere

Department of Perfusion University Hospital Gent

G. Van Nooten

Department of Cardiac Surgery, University Hospital Gent

Five infants with congenital heart disease were perfused with the D-901 neonatal oxygenator at the time of their cardiac surgery. The ability to reduce the prime volume below the blood volume as well as the blood handling and gas transfer characteristics were studied.

In all cases the prime volume was less than or equal to the blood volume of the patient. This resulted in a reduction in the use of homologous blood products. Due to the concept of the D-901 it was possible to adapt the tubing in such a way that a complete prime of 220 ml was obtained. The device had a maximum oxygen transfer of 45 ml/min. The maximum carbon dioxide removal was 50 ml/min at a blood gas ratio of one.

The mean platelet count post bypass decreased to 91 % of the baseline value. Mean free haemoglobin levels increased to 86 mg/100 ml at 120 minutes of bypass.

We conclude that the D-901 oxygenator opens new perspectives for perfusion in small babies in terms of priming volume and use of homologous blood products while maintaining good gas transfer characteristics. However, larger series are necessary to expand our experience with this device and its limitations.

No specific problems related to the device were encountered and all infants had an uneventful postoperative course.

Perfusion, Vol. 9, No. 5, 349-355 (1994)
DOI: 10.1177/026765919400900507


Add to CiteULike CiteULike   Add to Complore Complore   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati   Add to Twitter Twitter    What's this?


This article has been cited by other articles:


Home page
PerfusionHome page
F. De Somer, L. Foubert, J. Poelaert, D. Dujardin, G. Van Nooten, and K. Francois
Low extracorporeal priming volumes for infants: a benefit?
Perfusion, November 1, 1996; 11(6): 455 - 460.
[Abstract] [PDF]