Advanced Search

Journal Navigation

Journal Home

Subscriptions

Archive

Contact Us

Table of Contents

Sign In to gain access to subscriptions and/or personal tools.
Perfusion
This Article
Right arrow Full Text (PDF)
Right arrow References
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Saved Citations
Right arrow Download to citation manager
Right arrowRequest Permissions
Right arrow Request Reprints
Right arrow Add to My Marked Citations
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Right arrow Citing Articles via Scopus
Google Scholar
Right arrow Articles by Wolvek, S.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Wolvek, S.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati  
What's this?

The hostile environment of the aging human aorta and the smaller patient- their implications for the intra-aortic balloon

Sidney Wolvek

Cardiac Assist Division, Datascope Corp., 3 Fir Court, PO Box 3100, Oakland, NJ 07436, USA

Intra-aortic balloon counterpulsation (IABC) has been a clinical modality since 1968. In the intervening years the patient population has become older, sicker and smaller. Modern balloon design permits the insertion of balloons into this evolving patient population and the balloon is increasingly threatened by the calcific plaque of the aging aorta and by the geometry of the shorter descending thoracic aorta in the smaller patient. Balloon sizing consideration and radiographic verification of balloon position within the aorta will reduce the incidence of balloon damage during IABC.

Perfusion, Vol. 9, No. 2, 87-94 (1994)
DOI: 10.1177/026765919400900202


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati    What's this?


This article has been cited by other articles:


Home page
ICVTSHome page
H. Parissis, M. Leotsinidis, D. Dougenis, and D. Richens
The way the intra-aortic balloon catheter moves within the aorta as a possible mechanism of balloon associated morbidity
Interactive CardioVascular and Thoracic Surgery, August 1, 2007; 6(4): 425 - 429.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
S. Wolvek
Intraaortic Balloon Rupture: A Possible Means of Prevention
Ann. Thorac. Surg., April 1, 1995; 59(4): 1041 - 1041.
[Full Text]