Advanced Search

Journal Navigation

Journal Home

Subscriptions

Archive

Contact Us

Table of Contents

Sign In to gain access to subscriptions and/or personal tools.
Perfusion
This Article
Right arrow Full Text (PDF)
Right arrow References
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Saved Citations
Right arrow Download to citation manager
Right arrowRequest Permissions
Right arrow Request Reprints
Right arrow Add to My Marked Citations
Citing Articles
Right arrow Citing Articles via Google Scholar
Right arrow Citing Articles via Scopus
Google Scholar
Right arrow Articles by Fried, D. W
Right arrow Articles by Bell-Thomson, J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Fried, D. W
Right arrow Articles by Bell-Thomson, J.
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati   Add to Twitter  
What's this?

Oxygen transfer performance of a new Sarns membrane oxygenator

David W Fried

Division of Cardiothoracic Surgery, Albert Einstein Medical Center, Philadelphia

John Bell-Thomson

Division of Cardiothoracic Surgery, Albert Einstein Medical Center, Philadelphia

Oxygen transfer performance of the SMO2, a new hollow-fibre membrane oxygenator from Sarns/3M, was evaluated. The maximum oxygen transfer of the SMO2 (504 ml O2/min) was 57% higher than that for the SMO. This was true even though the membrane surface area increased by only 11 % (1.8 m2 to 2.0 m2). The average gas phase-arterial oxygen gradient and the average shunt fraction was decreased by 35% and 30% respectively. The diffusing capacity of the SMO2 was increased by 74% over the SMO. The oxygen transfer performance compared favourably, not only to the SMO, but to five other previously evaluated membrane oxygenators. It performed better in each category regardless of whether the result was expressed in absolute terms or relative to membrane surface area.

Perfusion, Vol. 7, No. 4, 263-271 (1992)
DOI: 10.1177/026765919200700404


Add to CiteULike CiteULike   Add to Complore Complore   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati   Add to Twitter Twitter    What's this?