Advanced Search

Journal Navigation

Journal Home

Subscriptions

Archive

Contact Us

Table of Contents

Sign In to gain access to subscriptions and/or personal tools.
Perfusion
This Article
Right arrow Full Text (PDF)
Right arrow References
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Alert me to new issues of the journal
Right arrow Add to Saved Citations
Right arrow Download to citation manager
Right arrowRequest Permissions
Right arrow Request Reprints
Right arrow Add to My Marked Citations
Citing Articles
Right arrow Citing Articles via Google Scholar
Right arrow Citing Articles via Scopus
Google Scholar
Right arrow Articles by Vainionpää, V.
Right arrow Articles by Timisjärvi, J.
Right arrow Search for Related Content
PubMed
Right arrow Articles by Vainionpää, V.
Right arrow Articles by Timisjärvi, J.
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati   Add to Twitter  
What's this?

Vasomotor waves of arterial blood pressure after cessation of cardiopulmonary bypass in man

V. Vainionpää

Department of Anesthesiology University of Oulu

A. Hollme'n

Department of Anesthesiology University of Oulu

J. Timisjärvi

Department of Physiology, University of Oulu, Oulu, Finland

The occurrence of vasomotor waves during cardiopulmonary bypass (CPB) is a recognized phenomenon. The lesser known oscillation of arterial pressure after cessation of CPB was observed in 18 open-heart patients. The duration of an oscillatory wave was 13.5±5.0 seconds, the amplitude 6.1 ±2.6mmNg and the mean arterial pressure 76.5± 10.7mmHg. Inter-and also intraindividual variations in frequency and amplitude of the oscillation, however, did occur. In 13 patients, this oscillation occurred during ventricular epicardial pacing. The oscillation continued until the end of the operation in eight patients; in others, the oscillation was of shorter duration. An oscillation of pulmonary arterial pressure (PAP) was simultaneously observed in nine patients (eight with pacemaker) and central venous pressure (CVP) oscillation in eight patients (all with pacemaker). The duration of a wave was the same as in systemic arterial pressure and the amplitudes were 1.5-3.0mmHg in PAP and 1.0-2.0mmHg in CVP. These arterial vasomotor waves, seen here after CPB, largely resemble those observed during perfusion in man and also the Mayerwaves explored in experimental animals. The pacing rhythm seems to favourthe appearance of those blood pressure oscillations.

Perfusion, Vol. 5, No. 4, 261-266 (1990)
DOI: 10.1177/026765919000500404