Advanced Search

Journal Navigation

Journal Home

Subscriptions

Archive

Contact Us

Table of Contents

Sign In to gain access to subscriptions and/or personal tools.
Perfusion
This Article
Right arrow Full Text (PDF)
Right arrow References
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Alert me to new issues of the journal
Right arrow Add to Saved Citations
Right arrow Download to citation manager
Right arrowRequest Permissions
Right arrow Request Reprints
Right arrow Add to My Marked Citations
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Right arrow Citing Articles via Scopus
Google Scholar
Right arrow Articles by von Segesser, L.
Right arrow Articles by Turina, M.
Right arrow Search for Related Content
PubMed
Right arrow Articles by von Segesser, L.
Right arrow Articles by Turina, M.
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati   Add to Twitter  
What's this?

Experimental evaluation of the Dideco Masterflo paediatric hollow-fibre membrane oxygenator

L. von Segesser

University Hospital, Zurich

B. Leskosek

University Hospital, Zurich

F. Redha

University Hospital, Zurich

E. Garcia

University Hospital, Zurich

M. Turina

University Hospital, Zurich

Nine mongrel dogs (mean bodyweight: 29 ± 6kg) were connected to cardiopulmonary bypass byfemorojugularvenous and femoral arterial cannulation, classic roller pump and the integrated Dideco D702 Masterflo hollow-fibre membrane oxygenatorwith a mean flow rate of 70ml/kg/min for six hours. Then the animals were weaned from cardiopulmonary bypass and thereafter weaned from the ventilator. After seven days all animals were sacrificed electively for necropsy. A standard battery of blood samples was taken before the bypass, after mixing (10 minutes), after two hours, five hours and six hours of perfusion. Further samples were taken 30 minutes after bypass (spontaneous breathing), 60 minutes after bypass (after extubation), 24 hours after bypass, 48 hours after bypass and seven days after bypass. Physiologic blood gas values could be maintained throughout perfusion in all animals. Mean arterial oxygen saturation varied between 99.7% and 99.9% for the arterial side of the oxygenator compared to 77.8% and 86.6% on the venous side. Post bypass blood gas analyses showed physiologic values and no evidence of major lung trauma or pulmonary oedema in relation to the six hours' bypass. Red blood count was 5.84 ± 0.02 before and 4.63 + 0.1 million/mm3 after mixing and dropped to 3.89 ± 0.52 till the end of the bypass. After seven days the red blood count was practically normalized with over 5,000,000 erythrocytes per mm3 at the end of the observation. Blood trauma evaluated in function of plasma haemoglobin and (thrombocyte) depletion showed the following results: prebypass: 2.3 ± 0.7 µmol/l plasma haemoglobin and (220 ± 24 thousand thrombocytes per mm3); after six hours perfusion: 26.2 ± 15.5 and (137 ± 12); after seven days: 9.3 ± 4.1 and (400 ± 125). Post mortem studies did not demonstrate any deleterious lesions.

Perfusion, Vol. 4, No. 3, 223-234 (1989)
DOI: 10.1177/026765918900400308


Add to CiteULike CiteULike   Add to Complore Complore   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati   Add to Twitter Twitter    What's this?


This article has been cited by other articles:


Home page
PerfusionHome page
X. M Mueller, H. T Tevaearai, M. Augstburger, J. Horisberger, and L K von Segesser
Experimental evaluation of the Dideco D903 Avant 1.7 hollow-fibre membrane oxygenator
Perfusion, September 1, 1998; 13(5): 353 - 359.
[Abstract] [PDF]