Advanced Search

Journal Navigation

Journal Home

Subscriptions

Archive

Contact Us

Table of Contents

Click here to sign up for SAGE Journal Email Alerts today!

Sign In to gain access to subscriptions and/or personal tools.
Perfusion
This Article
Right arrow Full Text (PDF)
Right arrow References
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Saved Citations
Right arrow Download to citation manager
Right arrowRequest Permissions
Right arrow Request Reprints
Right arrow Add to My Marked Citations
Citing Articles
Right arrow Citing Articles via Google Scholar
Right arrow Citing Articles via Scopus
Google Scholar
Right arrow Articles by Puri, G.
Right arrow Articles by Rana, S.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Puri, G.
Right arrow Articles by Rana, S.
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati   Add to Twitter  
What's this?

research-article

Cerebral venous congestion during cardio-pulmonary bypass: role of bispectral index monitoring

GD Puri

Department of Anesthesia and Intensive Care, Postgraduate Institute of Medical Education and Research, Chandigarh, India gdpuri007{at}hotmail.com

J Agarwal

Department of Anesthesia and Intensive Care, Postgraduate Institute of Medical Education and Research, Chandigarh, India

A Solanki

Department of Anesthesia and Intensive Care, Postgraduate Institute of Medical Education and Research, Chandigarh, India

SS Rana

Department of Cardiothoracic and Vascular Surgery, Postgraduate Institute of Medical Education and Research, Chandigarh, India

A 58-year-old male patient was posted for double valve replacement under hypothermic cardiopulmonary bypass (CPB). During aortic cross-clamp (AXC), the central venous pressure (CVP) was found to have increased to 22 mmHg. After 4 minutes of sustained increase in CVP, burst suppression (SR) started increasing. After 5 min of increase in SR, bispectral index (BIS) declined rapidly to 17. Propofol infusion was stopped and re-evaluation of signs of facial congestion showed changes to that effect. The perfusionist noted steadily decreasing venous return. As soon as the superior vena cava (SVC) cannula was withdrawn by 3 cm, CVP immediately declined to 6 mmHg. The venous return in the CPB reservoir normalized and BIS returned to 42 after a transient rise to a maximum of 58 and SR decreased to 0 within 2 min of repositioning of the venous cannula. The patient was successfully extubated after 7 hours without any sequelae.

Key Words: bispectral index • burst suppression ratio • central venous pressure

Perfusion, Vol. 23, No. 3, 153-155 (2008)