Advanced Search

Journal Navigation

Journal Home

Subscriptions

Archive

Contact Us

Table of Contents

Click here to sign up for SAGE Journal Email Alerts today!

Sign In to gain access to subscriptions and/or personal tools.
Perfusion
This Article
Right arrow Full Text (PDF)
Right arrow References
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in ISI Web of Science
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Saved Citations
Right arrow Download to citation manager
Right arrowRequest Permissions
Right arrow Request Reprints
Right arrow Add to My Marked Citations
Citing Articles
Right arrow Citing Articles via Google Scholar
Right arrow Citing Articles via Scopus
Google Scholar
Right arrow Articles by Ganushchak, Y
Right arrow Articles by de Jong, D S
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Ganushchak, Y
Right arrow Articles by de Jong, D S
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati  
What's this?

Hydrodynamic performance and heat generation by centrifugal pumps

Y Ganushchak

Department of Extra-Corporeal Circulation, University Hospital Maastricht, Maastricht, the Netherlands, yga{at}scpc.azm.nl

W van Marken Lichtenbelt

Department of Human Biology, Maastricht University, Maastricht, the Netherlands

T van der Nagel

Department of Cardio-Thoracic Surgery, University Hospital Maastricht, Maastricht, the Netherlands

D S de Jong

Department of Extra-Corporeal Circulation, University Hospital Maastricht, Maastricht, the Netherlands

For over a century, centrifugal pumps (CP) have been used in various applications, from large industrial pumps to flow pumps for aquariums. However, the use of CP as blood pumps has a rather short history. Consequently, the hydraulic performance data for a blood CP are limited. The aim of our investigation was to study the hydraulic performance and the heat generation of three commercially available CP: Bio-Medicus Bio-Pump BP80 (Medtronic), Rotaflow (Jostra Medizintechnik), and DeltaStreamTM DP2 (MEDOS Medizintechnik AQ).

The study was performed using a circuit primed with a water-glycerin mixture with a dynamic viscosity of 0.00272 pa/s. Pressure-flow curves were obtained by a stepwise stagnation of the pump outlet or inlet. The temperature changes were observed using ThermaCAM SC2000 (Flir Systems).

The pumps’ performance in close to clinical conditions (‘operating region’) was analysed in this report. The ‘operating region’ in the case of the BP80 is positioned around the pressure-flow curve at a pump speed of 3000 rpm. In the case of the Rotaflow, the ‘operating region’ was between the pump pressure-flow curves at a speed of 3000 and 4000 rpm, and the DP2 was found between 7000 and 8000 rpm.

The standard deviation of mean pressure through the pump was used to characterise the stability of the pump. In experiments with outlet stagnation, the BP80 demonstrated high negative association between flow and pressure variability (r=-0.68, p <0.001). In experiments with the DP2, this association was positive (r=-0.68, pB <0.001). All pumps demonstrated significantly higher variability of pressure in experiments with inlet stagnation in comparison to the experiments with outlet stagnation.

The rise of relative temperature in the inlet of a pump was closely related to the flow rate. The heating of fluid was more pronounced in the ‘zero-flow’ mode, especially in experiments with inlet stagnation.

In summary, (1) the ‘zero-flow’ regime, which is described in the manuals of some commercially-available pumps, is the use of the pump outside the allowable operating region. It is potentially dangerous and should, therefore, never be used in clinical settings. (2) Using centrifugal pumps for kinetic-assisted venous return can only be performed safely when the negative pressure at the inlet of the pump is monitored continuously. The maximum allowable negative pressure has to be defined for each type of pump, and must be based on pump performance.

Perfusion, Vol. 21, No. 6, 373-379 (2006)
DOI: 10.1177/0267659106074003


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati    What's this?