Perfusion

 

Advanced Search

Journal Navigation

Journal Home

Subscriptions

Archive

Contact Us

Table of Contents

Sign In to gain access to subscriptions and/or personal tools.
This Article
Right arrow Full Text (PDF)
Right arrow References
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Saved Citations
Right arrow Download to citation manager
Right arrowRequest Permissions
Right arrow Request Reprints
Right arrow Add to My Marked Citations
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Groom, R C
Right arrow Articles by Morton, J
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Groom, R C
Right arrow Articles by Morton, J
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati  
What's this?
Perfusion, Vol. 17, No. 6, 447-450 (2002)
DOI: 10.1191/0267659102pf606oa

Parallel replacement of the oxygenator that is not transferring oxygen: the PRONTO procedure

R C Groom

Maine Medical Center, Portland, Maine, USA, groomr{at}mmc.org

R J Forest

Maine Medical Center, Portland, Maine, USA

J E Cormack

Maine Medical Center, Portland, Maine, USA

K S Niimi

Maine Medical Center, Portland, Maine, USA

J Morton

Maine Medical Center, Portland, Maine, USA

We present here a technique to replace a failed oxygenator by inserting a second oxygenator in parallel (PRONTO) within the cardiopulmonary bypass (CPB) circuit. Oxygenator failure is a potential hazard that may result in patient injury or death. Although failures are rare, safety surveys conducted over the last 25 years suggest that the incidence of oxygenator failures is on the rise. This emergency procedure may be easily applied to any standard CPB circuit with a few minor alterations. The technique is simple; it can be carried out rapidly. An important advantage of this technique is that it may be executed without interrupting blood flow to the patient, which may reduce the incidence of patient injury or death.


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati    What's this?


This article has been cited by other articles:


Home page
PerfusionHome page
U Da Broi, V Adami, E Falasca, W Malangone, S Crini, and A Degrassi
A new oxygenator change-out system and procedure
Perfusion, September 1, 2006; 21(5): 297 - 303.
[Abstract] [PDF]