|
Sign In to gain access to subscriptions and/or personal tools.
|
Heparin-coated cardiopulmonary bypass circuits: current status
Li-Chien Hsu
Edwards Lifesciences LLC, Irvine, California, LCHsu{at}therox.com
Heparin-coated circuits have been subjected to vigorous testing, both experimentally and clinically, for the past decade. When the functions of heparin are preserved on the surface, the heparinized surface plays multiple roles in attenuating the systemic inflammatory response. These include the ability to attenuate contact activation, coagulation activation, complement activation and, directly or indirectly, platelet and leukocyte activation. The heparinized surface also renders the cardiopulmonary bypass (CPB) circuits hydrophilic and protein resistant and augments lipoprotein binding. The multifunctional nature of the heparinized surface contributes to the overall biocompatibility of the surface. Clinically, heparin-coated circuits become most effective in reducing systemic inflammatory response and in improving morbidity, mortality, and other patient outcome related parameters when material-independent blood activation is controlled or minimized through a global biocompatibility strategy. Techniques involved in the global biocompatibility strategy are readily available and are being effectively and safely practiced at several centers. With the global biocompatibility strategy, outstanding and reproducible results have been routinely achieved with conventional CPB techniques. Alternative revascularization procedures should equal or surpass conventional CPB, using best clinically proven strategies with respect to patient outcome and long-term graft patency.
Perfusion, Vol. 16, No. 5,
417-428 (2001)
DOI: 10.1177/026765910101600512

CiteULike Connotea Del.icio.us Digg Reddit Technorati What's this?
This article has been cited by other articles:

|
 |

|
 |
 
I. Groth, N. Grunewald, and S. Alban
Pharmacological profiles of animal- and nonanimal-derived sulfated polysaccharides - comparison of unfractionated heparin, the semisynthetic glucan sulfate PS3, and the sulfated polysaccharide fraction isolated from Delesseria sanguinea
Glycobiology,
April 1, 2009;
19(4):
408 - 417.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
J. W. Hammon
Extracorporeal Circulation: Perfusion System
Card. Surg. Adult,
January 1, 2008;
3(2008):
350 - 370.
[Full Text]
|
 |
|

|
 |

|
 |
 
L. Simonardottir, B. Torfason, E. Stefansson, and J. Magnusson
Changes in muscle compartment pressure after cardiopulmonary bypass
Perfusion,
May 1, 2006;
21(3):
157 - 163.
[Abstract]
[PDF]
|
 |
|

|
 |

|
 |
 
K. A Samolyk, S. R Beckmann, and R. C Bissinger
A new practical technique to reduce allogeneic blood exposure and hospital costs while preserving clotting factors after cardiopulmonary bypass: the Hemobag(R)
Perfusion,
December 1, 2005;
20(6):
343 - 349.
[Abstract]
[PDF]
|
 |
|

|
 |

|
 |
 
K. T. Lappegard, J. Riesenfeld, O.-L. Brekke, G. Bergseth, J. D. Lambris, and T. E. Mollnes
Differential Effect of Heparin Coating and Complement Inhibition on Artificial Surface-Induced Eicosanoid Production
Ann. Thorac. Surg.,
March 1, 2005;
79(3):
917 - 923.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
J.P. Remadi, Z. Rakotoarivello, P. Marticho, F. Trojette, A. Benamar, H. Poulain, and C. Tribouilloy
Aortic valve replacement with the minimal extracorporeal circulation (Jostra MECC System) versus standard cardiopulmonary bypass: A randomized prospective trial
J. Thorac. Cardiovasc. Surg.,
September 1, 2004;
128(3):
436 - 441.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
K. T. Lappegard, M. Fung, G. Bergseth, J. Riesenfeld, and T. E. Mollnes
Artificial surface-induced cytokine synthesis: effect of heparin coating and complement inhibition
Ann. Thorac. Surg.,
July 1, 2004;
78(1):
38 - 44.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
T. N Hoel, V. Videm, S. T Baksaas, T. E Mollnes, F. Brosstad, and J. L Svennevig
Comparison of a Duraflo II-coated cardiopulmonary bypass circuit and a trillium-coated oxygenator during open-heart surgery
Perfusion,
May 1, 2004;
19(3):
177 - 184.
[Abstract]
[PDF]
|
 |
|

|
 |

|
 |
 
K. T. Lappegard, M. Fung, G. Bergseth, J. Riesenfeld, J. D. Lambris, V. Videm, and T. E. Mollnes
Effect of complement inhibition and heparin coating on artificial surface-induced leukocyte and platelet activation
Ann. Thorac. Surg.,
March 1, 2004;
77(3):
932 - 941.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
B. Meng, X. H. Wang, F. Z. Cui, H. Y. Dong, and F. Yu
A New Method of Heparinizing PLLA Film by Surface Entrapment
Journal of Bioactive and Compatible Polymers,
March 1, 2004;
19(2):
131 - 143.
[Abstract]
[PDF]
|
 |
|

|
 |

|
 |
 
E. A. Hessel II and L. H. Edmunds Jr.
Extracorporeal Circulation: Perfusion Systems
Card. Surg. Adult,
January 1, 2003;
2(2003):
317 - 338.
[Full Text]
|
 |
|

|
 |

|
 |
 
V. Vijay and K. McCusker
Recent advances in biocompatible surface-modifying additives for cardiopulmonary bypass
Perfusion,
January 1, 2003;
18(1_suppl):
41 - 45.
[PDF]
|
 |
|
|
|