Advanced Search

Journal Navigation

Journal Home

Subscriptions

Archive

Contact Us

Table of Contents

Sign In to gain access to subscriptions and/or personal tools.
Perfusion
This Article
Right arrow Full Text (PDF)
Right arrow References
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Saved Citations
Right arrow Download to citation manager
Right arrowRequest Permissions
Right arrow Request Reprints
Right arrow Add to My Marked Citations
Citing Articles
Right arrow Citing Articles via Google Scholar
Right arrow Citing Articles via Scopus
Google Scholar
Right arrow Articles by Jegger, D
Right arrow Articles by von Segesser, L K
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Jegger, D
Right arrow Articles by von Segesser, L K
Right arrowPubmed/NCBI databases
*Substance via MeSH
Medline Plus Health Information
*Blood Thinners
Hazardous Substances DB
*HEPARIN
*PROTAMINE
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati   Add to Twitter  
What's this?

Assembly of the Heparin Removal Device for patients with suspected adverse reaction to protamine sulphate

D Jegger

Department of Cardiovascular Surgery, University Hospital, Lausanne, david.jegger{at}chuv.hospvd.ch

H T Tevaearai

Department of Cardiovascular Surgery, University Hospital, Lausanne

J Horisberger

Department of Cardiovascular Surgery, University Hospital, Lausanne

X M Mueller

Department of Cardiovascular Surgery, University Hospital, Lausanne

I Seigneuil

Department of Cardiovascular Surgery, University Hospital, Lausanne

N Pierrel

Department of Cardiovascular Surgery, University Hospital, Lausanne

Y Boone

Department of Cardiovascular Surgery, University Hospital, Lausanne

L K von Segesser

Department of Cardiovascular Surgery, University Hospital, Lausanne

Protamine sulphate is routinely used after cardiopulmonary bypass (CPB) to restore the patient’s baseline coagulatory state. However, adverse reactions are encountered, and alternative means to neutralize heparin are, therefore, necessary. The Heparin Removal Device (HRD) constitutes an extracorporeal circuit that allows ex vivo deheparinization by mean of a polycationic ligand that binds heparin molecules.

This paper presents the setup of the HRD circuit. It is illustrated by the report of a 68-year-old man with a known severe crustacean allergy. The patient (78 kg, 170 cm) was admitted for elective coronary artery bypass graft surgery. It was decided that the HRD would be used as a precaution in order to avoid the risks of using protamine sulphate. The CPB time and aortic crossclamp time were 70 and 40 min, respectively. At the end of CPB, the device was inserted and processing started. Activated coagulation time values were monitored over a 130 min period and diminished from 480 to 300 s after 45 min, 220 s after 90 min, and settled at 150 s. Haemostasis was acceptable and processing stopped. The operation was terminated and the patient transferred to the intensive care unit. Clinical evolution was excellent, with minimal postoperative bleeding.

The HRD presents an alternative to protamine sulphate when this drug is contraindicated for a certain patient population who might have a suspected, known or emergency adverse reaction.

Perfusion, Vol. 15, No. 5, 453-456 (2000)
DOI: 10.1177/026765910001500508


Add to CiteULike CiteULike   Add to Complore Complore   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati   Add to Twitter Twitter    What's this?