Perfusion

 

Advanced Search

Journal Navigation

Journal Home

Subscriptions

Archive

Contact Us

Table of Contents

Sign In to gain access to subscriptions and/or personal tools.
This Article
Right arrow Full Text (PDF)
Right arrow References
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Saved Citations
Right arrow Download to citation manager
Right arrowRequest Permissions
Right arrow Request Reprints
Right arrow Add to My Marked Citations
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Joubert-Huebner, E
Right arrow Articles by Sievers, H-H
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Joubert-Huebner, E
Right arrow Articles by Sievers, H-H
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati  
What's this?
Perfusion, Vol. 15, No. 1, 69-76 (2000)
DOI: 10.1177/026765910001500110

An in vitro evaluation of a new cannula tip design compared with two clinically established cannula-tip designs regarding aortic arch vessel perfusion characteristics

E Joubert-Huebner

Department of Cardiac Surgery, Medical University of Luebeck, Luebeck

A Gerdes

Department of Cardiac Surgery, Medical University of Luebeck, Luebeck

H-H Sievers

Department of Cardiac Surgery, Medical University of Luebeck, Luebeck

We investigated in vitro aortic arch vessel perfusion characteristics of single and multiple jet-stream cannulae and a new dispersion stream tip aortic cannula. Pressures and flows of all arch vessels were measured while directing cannulae jets at the different arch vessels using 6 l/min pump flow. The highest increase in pressure above the set systemic level of 80 mmHg and increase in flow above the set normal flow distribution in the arch vessels occurred in the jet-streamed arch vessels with the single stream cannula. The values were as follows: 29 mmHg and 118 ml/min for the innominate artery, 28 mmHg and 42 ml/min for the left common carotid artery, and 25 mmHg and 54 ml/min for the left subclavian artery. The dispersion stream cannula showed increases in pressure and flow, followed by the multiple stream cannula. Aortic cannula tips and the orientation of jets are potential sources of imbalances of arch vessel perfusion with possible clinical implications regarding perfusion of arch vessels during extracorporeal circulation.


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati    What's this?


This article has been cited by other articles:


Home page
PerfusionHome page
M. N Andersen, S. Ringgaard, J M. Hasenkam, and H. Nygaard
Quantitative haemodynamic evaluation of aortic cannulas
Perfusion, September 1, 2004; 19(5): 323 - 330.
[Abstract] [PDF]


Home page
PerfusionHome page
A A Albert, C J Beller, B Arnrich, J A Walter, U P Rosendahl, A Hetzel, H Priss, and J Ennker
Is there any impact of the shape of aortic end-hole cannula on stroke occurrence? Clinical evaluation of straight and bent-tip aortic cannulae
Perfusion, December 1, 2002; 17(6): 451 - 456.
[Abstract] [PDF]


Home page
PerfusionHome page
A. Gerdes, T. Hanke, and H.-H Sievers
Hydrodynamics of the new Medos aortic cannula
Perfusion, May 1, 2002; 17(3): 217 - 220.
[Abstract] [PDF]