Advanced Search

Journal Navigation

Journal Home

Subscriptions

Archive

Contact Us

Table of Contents

Sign In to gain access to subscriptions and/or personal tools.
Perfusion
This Article
Right arrow Full Text (PDF)
Right arrow References
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Saved Citations
Right arrow Download to citation manager
Right arrowRequest Permissions
Right arrow Request Reprints
Right arrow Add to My Marked Citations
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Right arrow Citing Articles via Scopus
Google Scholar
Right arrow Articles by Mueller, X. M
Right arrow Articles by von Segesser, L. K
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Mueller, X. M
Right arrow Articles by von Segesser, L. K
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati   Add to Twitter  
What's this?

Ex vivo testing of the Quart® arterial line filter

Xavier M Mueller

Clinic for Cardiovascular Surgery, Centre Hospitalier Universitaire, Lausanne, Xavier.Mueller{at}chuv.hospvd.ch

Hendrick T Tevaearai

Clinic for Cardiovascular Surgery, Centre Hospitalier Universitaire, Lausanne

David Jegger

Clinic for Cardiovascular Surgery, Centre Hospitalier Universitaire, Lausanne

Monique Augstburger

Clinic for Cardiovascular Surgery, Centre Hospitalier Universitaire, Lausanne

Marco Burki

Clinic for Cardiovascular Surgery, Centre Hospitalier Universitaire, Lausanne

Ludwig K von Segesser

Clinic for Cardiovascular Surgery, Centre Hospitalier Universitaire, Lausanne

Arterial line filters are now routinely used in cardiac surgery in order to decrease the microemboli load to the patient. The Quart® filter (Jostra, Hirrlingen, Germany) with a new planar construction design, an easy de-airing system and an integrated bypass, was tested for air filtration capacity and resistance to blood path in a standardized setting with surviving animals.

Three calves (mean body weight: 71 ± 3.4 kg) were connected to a standard cardiopulmonary bypass (CPB) circuit by jugular venous and carotid arterial cannulation with a mean flow rate of 3.5 l/min. The arterial line filter was challenged with upstream injections of boluses of air of 5, 10 and 15 ml, respectively. A Doppler ultrasound was positioned downstream on the arterial line to measure bubble count and size. The pressure drop through the filter was monitored at flow rates of between 1 and 6 l/min. At the end of the procedure the animals were weaned from the CPB and, thereafter, from the ventilator. After 7 days, the animals were sacrificed electively.

This study shows that important quantities of air can be injected into the arterial line upstream of the filter with small volumes of small sized bubbles recorded downstream. With the 5 ml air bolus injection, mean values of 0.3 ± 0.6 bubbles of 30 and 40 µm were detected, whereas with the 20 ml bolus, 32.6 ± 8.7 bubbles of 10 µm, 3.7 ± 1.1 bubbles of 30 µm, 3.3 ± 0.6 bubbles of 40 µm and 0.7 ± 1.1 bubbles of 50 µm were recorded. The blood path resistance at different blood flow rates was well within the acceptable range with a pressure drop of 20 ± 0 and 26.6 ± 5.7 mmHg at flow rates of 4 and 5 l/min, respectively.

With its planar concept, the Quart filter offers good air filtering capacity both in terms of bubble count and size after injection of large boluses of air, without any increase of resistance to the blood path. Moreover, it offers a venting function and an integrated bypass system.

Perfusion, Vol. 14, No. 6, 481-487 (1999)
DOI: 10.1177/026765919901400611


Add to CiteULike CiteULike   Add to Complore Complore   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati   Add to Twitter Twitter    What's this?


This article has been cited by other articles:


Home page
PerfusionHome page
J. Lynch and J. Riley
Microemboli detection on extracorporeal bypass circuitsa
Perfusion, January 1, 2008; 23(1): 23 - 32.
[Abstract] [PDF]


Home page
ChestHome page
M. Barak and Y. Katz
Microbubbles: Pathophysiology and Clinical Implications
Chest, October 1, 2005; 128(4): 2918 - 2932.
[Abstract] [Full Text] [PDF]


Home page
PerfusionHome page
M. Kurusz and B. D Butler
Bubbles and bypass: an update
Perfusion, January 1, 2004; 19(1_suppl): S49 - S55.
[Abstract] [PDF]