Advanced Search

Journal Navigation

Journal Home

Subscriptions

Archive

Contact Us

Table of Contents

Sign In to gain access to subscriptions and/or personal tools.
Perfusion
This Article
Right arrow Full Text (PDF)
Right arrow References
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Saved Citations
Right arrow Download to citation manager
Right arrowRequest Permissions
Right arrow Request Reprints
Right arrow Add to My Marked Citations
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Right arrow Citing Articles via Scopus
Google Scholar
Right arrow Articles by Palanzo, D. A
Right arrow Articles by Castagna, J. M
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Palanzo, D. A
Right arrow Articles by Castagna, J. M
Right arrowPubmed/NCBI databases
*Substance via MeSH
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati   Add to Twitter  
What's this?

Effect of TrilliumTM Biopassive Surface coating of the oxygenator on platelet count drop during cardiopulmonary bypass

David A Palanzo

Lehigh Valley Hospital, Allentown, Pennsylvania, David.Palanzo{at}LVH.com

Debra L Zarro

Lehigh Valley Hospital, Allentown, Pennsylvania

Ralph M Montesano

Lehigh Valley Hospital, Allentown, Pennsylvania

Norman J Manley

Lehigh Valley Hospital, Allentown, Pennsylvania

Michael Quinn

Lehigh Valley Hospital, Allentown, Pennsylvania

Barbara-Anne Elmore

Lehigh Valley Hospital, Allentown, Pennsylvania

Patricia A Gustafson

Lehigh Valley Hospital, Allentown, Pennsylvania

Joseph M Castagna

Lehigh Valley Hospital, Allentown, Pennsylvania

The new TrilliumTM Biopassive Surface is a coating designed to minimize the adsorption of protein and the attachment of cells. In previous studies, we were able to demonstrate that, by coating the bypass circuit with small amounts of albumin, the drop in circulating platelet count seen with the newer low-prime hollow-fiber membrane oxygenators is eliminated.

A study was undertaken to compare the Avecor AffinityTM oxygenator with albumin in the prime with the Trillium-coated Affinity. Fifty-six patients undergoing nonemergency open-heart surgery were randomly divided into two groups. One group (Albumin) received the Affinity oxygenator with 10 ml of 25% albumin added to the pump prime. The other group (Trillium) received the Trillium-coated Affinity oxygenator. To normalize the data for the effects of hemodilution, the mean net platelet count drop on bypass was calculated for each group. The Albumin group had a net platelet count drop of 0.81 ± 9.78%, while the Trillium group had a drop of 1.58 ± 13.0%. There was no significant statistical difference between the two groups.

From our investigation, we concluded that Trillium Biopassive Surface coating affords the Affinity oxygenator the same protective effects on circulating platelet counts as adding albumin to the prime.

Perfusion, Vol. 14, No. 6, 473-479 (1999)
DOI: 10.1177/026765919901400610


Add to CiteULike CiteULike   Add to Complore Complore   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati   Add to Twitter Twitter    What's this?


This article has been cited by other articles:


Home page
Anesth. Analg.Home page
J. Boldt, S. Suttner, C. Brosch, A. Lehmann, K. Rohm, and A. Mengistu
Cardiopulmonary Bypass Priming Using a High Dose of a Balanced Hydroxyethyl Starch Versus an Albumin-Based Priming Strategy
Anesth. Analg., December 1, 2009; 109(6): 1752 - 1762.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
D. Wang, S. D. Lick, X. Zhou, X. Liu, R. J. Benkowski, and J. B. Zwischenberger
Ambulatory Oxygenator Right Ventricular Assist Device for Total Right Heart and Respiratory Support
Ann. Thorac. Surg., November 1, 2007; 84(5): 1699 - 1703.
[Abstract] [Full Text] [PDF]


Home page
Eur. J. Cardiothorac. Surg.Home page
O. Mangoush, S. Purkayastha, S. Haj-Yahia, J. Kinross, M. Hayward, F. Bartolozzi, A. Darzi, and T. Athanasiou
Heparin-bonded circuits versus nonheparin-bonded circuits: an evaluation of their effect on clinical outcomes
Eur. J. Cardiothorac. Surg., June 1, 2007; 31(6): 1058 - 1069.
[Abstract] [Full Text] [PDF]


Home page
Anesth. Analg.Home page
C. W. Hogue Jr, C. A. Palin, and J. E. Arrowsmith
Cardiopulmonary bypass management and neurologic outcomes: an evidence-based appraisal of current practices.
Anesth. Analg., July 1, 2006; 103(1): 21 - 37.
[Abstract] [Full Text] [PDF]


Home page
PerfusionHome page
J. M van den Goor, W. van Oeveren, P. M Rutten, J. G Tijssen, and L. Eijsman
Adhesion of thrombotic components to the surface of a clinically used oxygenator is not affected by Trillium coating
Perfusion, May 1, 2006; 21(3): 165 - 172.
[Abstract] [PDF]


Home page
PerfusionHome page
J Dubois, L Jamaer, U Mees, J-L Pauwels, F Briers, J Lehaen, and M Hendrikx
Ex vivo evaluation of a new neonatal/infant oxygenator: comparison of the Terumo CAPIOX(R) Baby RX with Dideco Lilliput 1 and Polystan Safe Micro in the piglet model
Perfusion, September 1, 2004; 19(5): 315 - 321.
[Abstract] [PDF]


Home page
PerfusionHome page
T. N Hoel, V. Videm, S. T Baksaas, T. E Mollnes, F. Brosstad, and J. L Svennevig
Comparison of a Duraflo II-coated cardiopulmonary bypass circuit and a trillium-coated oxygenator during open-heart surgery
Perfusion, May 1, 2004; 19(3): 177 - 184.
[Abstract] [PDF]


Home page
PerfusionHome page
J. Noora, A. Lamy, K. M Smith, R. Kent, D. Batt, J. Fedoryshyn, and X. Wang
The effect of oxygenator membranes on blood: a comparison of two oxygenators in open-heart surgery
Perfusion, September 1, 2003; 18(5): 313 - 320.
[Abstract] [PDF]


Home page
PerfusionHome page
D. A Palanzo, D. L Zarro, N. J Manley, R. M Montesano, M. Quinn, B.-A. Elmore, P. A Gustafson, and J. M Castagna
Effect of Carmeda(R) BioActive Surface coating versus TrilliumTM Biopassive Surface coating of the oxygenator on circulating platelet count drop during cardiopulmonary bypass
Perfusion, July 1, 2001; 16(4): 279 - 283.
[Abstract] [PDF]