Perfusion

 

Advanced Search

Journal Navigation

Journal Home

Subscriptions

Archive

Contact Us

Table of Contents

Sign In to gain access to subscriptions and/or personal tools.
This Article
Right arrow Full Text (PDF)
Right arrow References
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Saved Citations
Right arrow Download to citation manager
Right arrowRequest Permissions
Right arrow Request Reprints
Right arrow Add to My Marked Citations
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Schaadt, J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Schaadt, J.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati  
What's this?
Perfusion, Vol. 14, No. 6, 425-435 (1999)
DOI: 10.1177/026765919901400605

Oxygenator thrombosis: an international phenomenon

Jennifer Schaadt

Department of Perfusion, West Roxbury VA Hospital, West Roxbury, Massachusetts, schaadt{at}usw.com

Oxygenator thrombosis, despite adequate anticoagulation, has become a recent concern amongst perfusionists worldwide. The phenomenon is characterized by a transient increase in oxygenator inlet pressure of up to 900 mmHg about 10-15 min after the institution of cardiopulmonary bypass (CPB). Depending on the size and location of the thrombus, shunting may occur that compromises gas transfer to the extent where oxygenator change-out is necessary. This article presents various case reports and publications, both domestic and international, detailing this phenomenon. Research hypothesizes that it is the activation of platelets that subsequently may cause the deposition of fibrin, yielding thrombus formation; however, the primary etiology of this phenomenon remains unknown. Possible catalysts include bypass techniques, equipment selection, pharmacological agents, prime and the patient. This paper will review all of the above with an emphasis on the often overlooked factor - the patient, as there are certain variables in patient hematology that provoke a hypercoagulable state leading to thrombosis, including blood type, genetics, age, disease state, gender and heparin.


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati    What's this?


This article has been cited by other articles:


Home page
PerfusionHome page
U Da Broi, V Adami, E Falasca, W Malangone, S Crini, and A Degrassi
A new oxygenator change-out system and procedure
Perfusion, September 1, 2006; 21(5): 297 - 303.
[Abstract] [PDF]


Home page
PerfusionHome page
J Dubois, L Jamaer, U Mees, J-L Pauwels, F Briers, J Lehaen, and M Hendrikx
Ex vivo evaluation of a new neonatal/infant oxygenator: comparison of the Terumo CAPIOX(R) Baby RX with Dideco Lilliput 1 and Polystan Safe Micro in the piglet model
Perfusion, September 1, 2004; 19(5): 315 - 321.
[Abstract] [PDF]


Home page
PerfusionHome page
J. Noora, A. Lamy, K. M Smith, R. Kent, D. Batt, J. Fedoryshyn, and X. Wang
The effect of oxygenator membranes on blood: a comparison of two oxygenators in open-heart surgery
Perfusion, September 1, 2003; 18(5): 313 - 320.
[Abstract] [PDF]


Home page
PerfusionHome page
A. R. Fisher, M. Baker, M. Buffin, P. Campbell, S. Hansbro, S. Kennington, A. Lilley, and M. Whitehorne
Normal and abnormal trans-oxygenator pressure gradients during cardiopulmonary bypass
Perfusion, January 1, 2003; 18(1): 25 - 30.
[Abstract] [PDF]


Home page
PerfusionHome page
R C Groom, R J Forest, J E Cormack, K S Niimi, and J Morton
Parallel replacement of the oxygenator that is not transferring oxygen: the PRONTO procedure
Perfusion, December 1, 2002; 17(6): 447 - 450.
[Abstract] [PDF]


Home page
PerfusionHome page
G J Myers, J F Legare, J A Sullivan, R B Leadon, R Johnstone, W Swyer, C Squires, C Power, and G M Hirsch
Use of autologous blood as part of the perfusate for cardiopulmonary bypass: a priming technique
Perfusion, May 1, 2002; 17(3): 211 - 216.
[Abstract] [PDF]


Home page
PerfusionHome page
H. P Wendel, A. Philipp, N. Weber, D. E Birnbaum, and G. Ziemer
Oxygenator thrombosis: worst case after development of an abnormal pressure gradient - incidence and pathway
Perfusion, July 1, 2001; 16(4): 271 - 278.
[Abstract] [PDF]


Home page
PerfusionHome page
P A. Segers, J F Heida, I de Vries, C Maas, A J Boogaart, and S Eilander
Clinical evaluation of nine hollow-fibre membrane oxygenators
Perfusion, March 1, 2001; 16(2): 95 - 106.
[Abstract] [PDF]


Home page
Eur. J. Cardiothorac. Surg.Home page
A. Liebold, C.M. Reng, A. Philipp, M. Pfeifer, and D.E. Birnbaum
Pumpless extracorporeal lung assist - experience with the first 20 cases
Eur. J. Cardiothorac. Surg., May 1, 2000; 17(5): 608 - 613.
[Abstract] [Full Text] [PDF]