Sign In to gain access to subscriptions and/or personal tools.
|
Oxygenator thrombosis: an international phenomenon
Jennifer Schaadt
Department of Perfusion, West Roxbury VA Hospital, West Roxbury, Massachusetts, schaadt{at}usw.com
Oxygenator thrombosis, despite adequate anticoagulation, has become a recent concern amongst perfusionists worldwide. The phenomenon is characterized by a transient increase in oxygenator inlet pressure of up to 900 mmHg about 10-15 min after the institution of cardiopulmonary bypass (CPB). Depending on the size and location of the thrombus, shunting may occur that compromises gas transfer to the extent where oxygenator change-out is necessary. This article presents various case reports and publications, both domestic and international, detailing this phenomenon. Research hypothesizes that it is the activation of platelets that subsequently may cause the deposition of fibrin, yielding thrombus formation; however, the primary etiology of this phenomenon remains unknown. Possible catalysts include bypass techniques, equipment selection, pharmacological agents, prime and the patient. This paper will review all of the above with an emphasis on the often overlooked factor - the patient, as there are certain variables in patient hematology that provoke a hypercoagulable state leading to thrombosis, including blood type, genetics, age, disease state, gender and heparin.
Perfusion, Vol. 14, No. 6,
425-435 (1999)
DOI: 10.1177/026765919901400605

CiteULike Complore Connotea Del.icio.us Digg Reddit Technorati Twitter What's this?
This article has been cited by other articles:

|
 |

|
 |
 
U Da Broi, V Adami, E Falasca, W Malangone, S Crini, and A Degrassi
A new oxygenator change-out system and procedure
Perfusion,
September 1, 2006;
21(5):
297 - 303.
[Abstract]
[PDF]
|
 |
|

|
 |

|
 |
 
J Dubois, L Jamaer, U Mees, J-L Pauwels, F Briers, J Lehaen, and M Hendrikx
Ex vivo evaluation of a new neonatal/infant oxygenator: comparison of the Terumo CAPIOX(R) Baby RX with Dideco Lilliput 1 and Polystan Safe Micro in the piglet model
Perfusion,
September 1, 2004;
19(5):
315 - 321.
[Abstract]
[PDF]
|
 |
|

|
 |

|
 |
 
J. Noora, A. Lamy, K. M Smith, R. Kent, D. Batt, J. Fedoryshyn, and X. Wang
The effect of oxygenator membranes on blood: a comparison of two oxygenators in open-heart surgery
Perfusion,
September 1, 2003;
18(5):
313 - 320.
[Abstract]
[PDF]
|
 |
|

|
 |

|
 |
 
A. R. Fisher, M. Baker, M. Buffin, P. Campbell, S. Hansbro, S. Kennington, A. Lilley, and M. Whitehorne
Normal and abnormal trans-oxygenator pressure gradients during cardiopulmonary bypass
Perfusion,
January 1, 2003;
18(1):
25 - 30.
[Abstract]
[PDF]
|
 |
|

|
 |

|
 |
 
R C Groom, R J Forest, J E Cormack, K S Niimi, and J Morton
Parallel replacement of the oxygenator that is not transferring oxygen: the PRONTO procedure
Perfusion,
December 1, 2002;
17(6):
447 - 450.
[Abstract]
[PDF]
|
 |
|

|
 |

|
 |
 
G J Myers, J F Legare, J A Sullivan, R B Leadon, R Johnstone, W Swyer, C Squires, C Power, and G M Hirsch
Use of autologous blood as part of the perfusate for cardiopulmonary bypass: a priming technique
Perfusion,
May 1, 2002;
17(3):
211 - 216.
[Abstract]
[PDF]
|
 |
|

|
 |

|
 |
 
H. P Wendel, A. Philipp, N. Weber, D. E Birnbaum, and G. Ziemer
Oxygenator thrombosis: worst case after development of an abnormal pressure gradient - incidence and pathway
Perfusion,
July 1, 2001;
16(4):
271 - 278.
[Abstract]
[PDF]
|
 |
|

|
 |

|
 |
 
P A. Segers, J F Heida, I de Vries, C Maas, A J Boogaart, and S Eilander
Clinical evaluation of nine hollow-fibre membrane oxygenators
Perfusion,
March 1, 2001;
16(2):
95 - 106.
[Abstract]
[PDF]
|
 |
|

|
 |

|
 |
 
A. Liebold, C.M. Reng, A. Philipp, M. Pfeifer, and D.E. Birnbaum
Pumpless extracorporeal lung assist - experience with the first 20 cases
Eur. J. Cardiothorac. Surg.,
May 1, 2000;
17(5):
608 - 613.
[Abstract]
[Full Text]
[PDF]
|
 |
|
|
|