Sign In to gain access to subscriptions and/or personal tools.
|
Vacuum assisted venous drainage (VAVD)
Karin Münster
University of Copenhagen and Hamlet Private Hospital, Copenhagen
Ulrich Andersen
University of Copenhagen and Hamlet Private Hospital, Copenhagen
Jens Mikkelsen
University of Copenhagen and Hamlet Private Hospital, Copenhagen
Gösta Pettersson
University of Copenhagen and Hamlet Private Hospital, Copenhagen, petterg{at}ccf.org
Poor venous drainage is a common problem in cardiac surgery, causing trouble for the surgeon and adverse effects to the patient. Smaller incisions for minimally invasive cardiac surgery require smaller venous catheters. In this study the function, safety and possible benefits of a system for vacuum assisted venous drainage has been tested experimentally and applied clinically. A vacuum regulator (The Hamlet box) and safety procedures were developed. The system was characterized in vitro in regard to the relationship between vacuum, catheter size, and blood temperature and flow. The clinical study included 54 adult patients, coronary artery bypass graft surgery and valve operations. Venous cannulation was bi-caval with two 24 Fr catheters. All the perfusions were essentially event free, and the system was easy to manage and regulate. Venous drainage was totally adequate, irrespective of the position of the heart, and less fluid was added during the perfusions (a median of 250 ml/patient compared to a median of 1000 ml/patient in the control group). There has been no evidence of increased haemolysis or other adverse effects. All patients were hospital survivors and had uneventful postoperative courses. Vacuum assisted venous drainage is now used routinely, and further studies are under way to develop the system and clarify the physiological effects.
Perfusion, Vol. 14, No. 6,
419-423 (1999)
DOI: 10.1177/026765919901400604

CiteULike Complore Connotea Del.icio.us Digg Reddit Technorati Twitter What's this?
This article has been cited by other articles:

|
 |

|
 |
 
P. Fernandes, J. MacDonald, A. Cleland, R. Mayer, S. Fox, and B. Kiaii
The use of a mini bypass circuit for minimally invasive mitral valve surgery
Perfusion,
May 1, 2009;
24(3):
163 - 168.
[Abstract]
[PDF]
|
 |
|

|
 |

|
 |
 
B. Kiaii, D. Bainbridge, and P. Fernandes
Surgical, Anesthetic, Perfusion-Related Advances in Minimal Access Surgery
Seminars in Cardiothoracic and Vascular Anesthesia,
December 1, 2007;
11(4):
282 - 287.
[Abstract]
[PDF]
|
 |
|

|
 |

|
 |
 
Y. J. Gu and P. W. Boonstra
Selection of priming solutions for cardiopulmonary bypass in adults
MMCTS,
January 9, 2006;
2006(0109):
1198.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
A. Fiorucci, P. S. Gerometta, M. DeVecchi, C. Guzman, M. L. Costantino, and V. Arena
In vitro assessment of the vacuum-assisted venous drainage (VAVD) system: risks and benefits
Perfusion,
March 1, 2004;
19(2):
113 - 117.
[Abstract]
[PDF]
|
 |
|

|
 |

|
 |
 
M. A Sobieski II, M. S Slaughter, D. E Hart, P. S Pappas, and A. J Tatooles
Peripheral cardiopulmonary bypass with modified assisted venous drainage and transthoracic aortic crossclamp: optimal management for robotic mitral valve repair
Perfusion,
September 1, 2003;
18(5):
307 - 311.
[Abstract]
[PDF]
|
 |
|

|
 |

|
 |
 
F De Somer, D De Wachter, P Verdonck, G Van Nooten, and T Ebels
Evaluation of different paediatric venous cannulae using gravity drainage and VAVD: an in vitro study
Perfusion,
September 1, 2002;
17(5):
321 - 326.
[Abstract]
[PDF]
|
 |
|

|
 |

|
 |
 
Y Tamari, K Lee-Sensiba, J Beck, R Chan, M Salogub, M Hall, T Lee, R Ganju, and L Mongero
A new top-loading venous bag provides vacuum-assisted venous drainage
Perfusion,
September 1, 2002;
17(5):
383 - 390.
[Abstract]
[PDF]
|
 |
|

|
 |

|
 |
 
S. Bevilacqua, S. Matteucci, M. Ferrarini, M. Kacila, A. Ripoli, A. Baroni, D. Mercogliano, M. Glauber, and P. Ferrazzi
Biochemical evaluation of vacuum-assisted venous drainage: a randomized, prospective study
Perfusion,
January 1, 2002;
17(1):
57 - 61.
[Abstract]
[PDF]
|
 |
|

|
 |

|
 |
 
K. Nakanishi, T. Shichijo, Y. Shinkawa, S. Takeuchi, M. Nakai, G. Kato, and O. Oba
Usefulness of vacuum-assisted cardiopulmonary bypass circuit for pediatric open-heart surgery in reducing homologous blood transfusion
Eur. J. Cardiothorac. Surg.,
August 1, 2001;
20(2):
233 - 238.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
S. Cirri, L. Negri, M. Babbini, G. Latis, B. Khlat, G. Tarelli, P. Panisi, E. Mazzaro, A. Bellisario, B. Borghetti, et al.
Haemolysis due to active venous drainage during cardiopulmonary bypass: comparison of two different techniques
Perfusion,
July 1, 2001;
16(4):
313 - 318.
[Abstract]
[PDF]
|
 |
|
|
|