Perfusion

 

Advanced Search

Journal Navigation

Journal Home

Subscriptions

Archive

Contact Us

Table of Contents

Register here to gain access to SAGE's 500+ Journals Online

Sign In to gain access to subscriptions and/or personal tools.
This Article
Right arrow Full Text (PDF)
Right arrow References
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Saved Citations
Right arrow Download to citation manager
Right arrowRequest Permissions
Right arrow Request Reprints
Right arrow Add to My Marked Citations
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by De Somer, F
Right arrow Articles by Van Nooten, G
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by De Somer, F
Right arrow Articles by Van Nooten, G
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati  
What's this?
Perfusion, Vol. 14, No. 5, 331-336 (1999)
DOI: 10.1177/026765919901400503

Nitric oxide donors attenuate increase in pressure drop across membrane oxygenators

F De Somer

Institute of Biomedical Technology, University Hospital, Gent, Filip.DeSomer{at}rug.ac.be

L Foubert

Institute of Biomedical Technology, University Hospital, Gent

E Schacht

Institute of Biomedical Technology, University Hospital, Gent

G Van Nooten

Institute of Biomedical Technology, University Hospital, Gent

We have evaluated the effect of nitric oxide (NO) on the pressure drop across a membrane oxygenator in one in vitro model and two in vivo models (using four dogs and five pigs). In all the experiments sodium nitroprusside (SNP) was used as a NO source, whereas gaseous NO was only used in the in vitro model. The drugs were given when the pressure drop or resistance across the device increased to at least twice the baseline values.

In the in vitro model, both SNP and gaseous NO decreased the pressure drop to 75% of its peak value after 10 min and to 67% after 20 min. In the dog model, resistance decreased from 390 to 153 mmHg/l/min after 5 min and to 85 mmHg/l/min after 20 min for a baseline value of 75 mmHg/l/min.

The initial resistance across the membrane oxygenator in the pig model increased from 6.6 ± 1.3 to 74 ± 38 mmHg/l/min. An infusion of 10 µg/kg/min SNP reduced the resistance to 16 ± 5 mmHg/l/min.