Advanced Search

Journal Navigation

Journal Home

Subscriptions

Archive

Contact Us

Table of Contents

Sign In to gain access to subscriptions and/or personal tools.
Perfusion
This Article
Right arrow Full Text (PDF)
Right arrow References
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Saved Citations
Right arrow Download to citation manager
Right arrowRequest Permissions
Right arrow Request Reprints
Right arrow Add to My Marked Citations
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Right arrow Citing Articles via Scopus
Google Scholar
Right arrow Articles by Fisher, A R
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Fisher, A R
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati   Add to Twitter  
What's this?

The incidence and cause of emergency oxygenator changeovers

A R Fisher

Heart and Lung Department, Harefield Hospital, Harefield, Middlesex

Emergency oxygenator changeover presents as an important potential hazard during cardiopulmonary bypass. In order to assess the frequency and possible causes of this event a retrospective survey was conducted of cardiothoracic units in the UK and Ireland. The survey was sent to these units in 1993 to cover the period from 1990 to 1992 inclusive and again in 1997 to cover the period from 1994 to 1996 inclusive. The total number of procedures reported in 1993 was 68 937 (response of 63%), among which there were 17 emergency oxygenator changeovers representing an incidence of one for every 4055 cases. The use of aprotinin was associated with nine of these incidents. Two other incidents occurred due to leaking oxygenators. The total number of procedures reported in 1997 was 97 313 (response of 70%), among which there were 21 emergency oxygenator changeovers, representing an incidence of one for every 4634 cases. The use of aprotinin was only associated with two of these incidents while seven were due to the development of a high trans-oxygenator pressure gradient and six occurred due to leaking oxygenators.

Perfusion, Vol. 14, No. 3, 207-212 (1999)
DOI: 10.1177/026765919901400309


Add to CiteULike CiteULike   Add to Complore Complore   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati   Add to Twitter Twitter    What's this?


This article has been cited by other articles:


Home page
Card Surg AdultHome page
J. W. Hammon
Extracorporeal Circulation: Perfusion System
Card. Surg. Adult, January 1, 2008; 3(2008): 350 - 370.
[Full Text]


Home page
PerfusionHome page
D. A Palanzo
Perfusion safety: defining the problem
Perfusion, July 1, 2005; 20(4): 195 - 203.
[Abstract] [PDF]


Home page
PerfusionHome page
J Dubois, L Jamaer, U Mees, J-L Pauwels, F Briers, J Lehaen, and M Hendrikx
Ex vivo evaluation of a new neonatal/infant oxygenator: comparison of the Terumo CAPIOX(R) Baby RX with Dideco Lilliput 1 and Polystan Safe Micro in the piglet model
Perfusion, September 1, 2004; 19(5): 315 - 321.
[Abstract] [PDF]


Home page
PerfusionHome page
R. Ginther Jr, R. Fillingham, B. Searles, and E. Darling
Departmental use of perfusion crisis management drills: 2002 survey results
Perfusion, September 1, 2003; 18(5): 299 - 302.
[Abstract] [PDF]


Home page
PerfusionHome page
J. Noora, A. Lamy, K. M Smith, R. Kent, D. Batt, J. Fedoryshyn, and X. Wang
The effect of oxygenator membranes on blood: a comparison of two oxygenators in open-heart surgery
Perfusion, September 1, 2003; 18(5): 313 - 320.
[Abstract] [PDF]


Home page
PerfusionHome page
A. R. Fisher, M. Baker, M. Buffin, P. Campbell, S. Hansbro, S. Kennington, A. Lilley, and M. Whitehorne
Normal and abnormal trans-oxygenator pressure gradients during cardiopulmonary bypass
Perfusion, January 1, 2003; 18(1): 25 - 30.
[Abstract] [PDF]


Home page
Card Surg AdultHome page
E. A. Hessel II and L. H. Edmunds Jr.
Extracorporeal Circulation: Perfusion Systems
Card. Surg. Adult, January 1, 2003; 2(2003): 317 - 338.
[Full Text]


Home page
PerfusionHome page
R C Groom, R J Forest, J E Cormack, K S Niimi, and J Morton
Parallel replacement of the oxygenator that is not transferring oxygen: the PRONTO procedure
Perfusion, December 1, 2002; 17(6): 447 - 450.
[Abstract] [PDF]


Home page
PerfusionHome page
A. H Stammers and B. L Mejak
An update on perfusion safety: does the type of perfusion practice affect the rate of incidents related to cardiopulmonary bypass?
Perfusion, May 1, 2001; 16(3): 189 - 198.
[Abstract] [PDF]