Advanced Search

Journal Navigation

Journal Home

Subscriptions

Archive

Contact Us

Table of Contents

Sign In to gain access to subscriptions and/or personal tools.
Perfusion
This Article
Right arrow Full Text (PDF)
Right arrow References
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Saved Citations
Right arrow Download to citation manager
Right arrowRequest Permissions
Right arrow Request Reprints
Right arrow Add to My Marked Citations
Citing Articles
Right arrow Citing Articles via Google Scholar
Right arrow Citing Articles via Scopus
Google Scholar
Right arrow Articles by Bellaiche, A. L.
Right arrow Articles by Christensen, T. D.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Bellaiche, A. L.
Right arrow Articles by Christensen, T. D.
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati   Add to Twitter  
What's this?

Venous saturation monitoring: reliability of the Bentley SM-0200 OxySAT with and without use of a cuvette

Anne Louise Bellaiche

Department of Cardio-thoracic and Vascular Surgery and Department of Experimental Clinical Research, Aarhus University Hospital, Skejby Hospital, Aarhus

Thomas Decker Christensen

Department of Cardio-thoracic and Vascular Surgery and Department of Experimental Clinical Research, Aarhus University Hospital, Skejby Hospital, Aarhus

In-line venous saturation monitoring is a useful method of quality management during extracorporeal circulation (ECC). The Bentley SM-0200 OxySAT® meter was tested with and without the use of the recommended cuvette. The study consisted of an in vitro part, where extremely low saturations could be safely measured, and an in vivo part, carried out under routine ECC conditions. The results show that the OxySAT® may be used with or without a cuvette, and that it needs calibration for optimal accuracy in either case.

Perfusion, Vol. 14, No. 1, 69-76 (1999)
DOI: 10.1177/026765919901400110


Add to CiteULike CiteULike   Add to Complore Complore   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati   Add to Twitter Twitter    What's this?