Perfusion

 

Advanced Search

Journal Navigation

Journal Home

Subscriptions

Archive

Contact Us

Table of Contents

Sign In to gain access to subscriptions and/or personal tools.
This Article
Right arrow Full Text (PDF)
Right arrow References
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Saved Citations
Right arrow Download to citation manager
Right arrowRequest Permissions
Right arrow Request Reprints
Right arrow Add to My Marked Citations
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Mahoney, C B.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Mahoney, C B.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati  
What's this?
Perfusion, Vol. 13, No. 3, 192-204 (1998)
DOI: 10.1177/026765919801300307

Heparin-bonded circuits: clinical outcomes and costs

C Brown Mahoney

Industrial Relations Center, Carlson School of Management, University of Minnesota, Minneapolis

The aim of this study was to use meta-analysis to combine the results of numerous studies and examine the impact of heparin-bonded circuits on clinical outcomes and the resulting costs. Heparin-bonded circuits, both ionically and covalently bonded, are examined separately.

The results of the study provide evidence that heparin-bonded circuits result in improved clinical outcomes when compared to the identical nonheparin-bonded circuits. These improved clinical outcomes result in subsequent lower costs per patient with their use. However, differences are apparent in the significance and magnitude of these outcomes between ionically and covalently bonded circuits. Covalently bonded circuits provide a greater magnitude and significance of improvement in clinical outcomes than ionically bonded circuits. Total cost savings can be expected to be three times greater with covalently bonded circuits ($3231 versus $1068).

It was concluded that the choice regarding the use of a heparin-bonded circuits and the type of heparin-bonded circuit used has the potential to alter clinical outcomes and subsequent costs. Cost consideration cannot be ignored, but clinical benefits should be the main rationale for the choice of cardiopulmonary bypass circuit. This analysis provides evidence that clinical benefits and cost savings can both be derived from use of the same technology - covalently bonded circuits.


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati    What's this?


This article has been cited by other articles:


Home page
Eur. J. Cardiothorac. Surg.Home page
O. Mangoush, S. Purkayastha, S. Haj-Yahia, J. Kinross, M. Hayward, F. Bartolozzi, A. Darzi, and T. Athanasiou
Heparin-bonded circuits versus nonheparin-bonded circuits: an evaluation of their effect on clinical outcomes
Eur. J. Cardiothorac. Surg., June 1, 2007; 31(6): 1058 - 1069.
[Abstract] [Full Text] [PDF]


Home page
J. Thorac. Cardiovasc. Surg.Home page
K. G. Shann, D. S. Likosky, J. M. Murkin, R. A. Baker, Y. R. Baribeau, G. R. DeFoe, T. A. Dickinson, T. J. Gardner, H. P. Grocott, G. T. O'Connor, et al.
An evidence-based review of the practice of cardiopulmonary bypass in adults: A focus on neurologic injury, glycemic control, hemodilution, and the inflammatory response.
J. Thorac. Cardiovasc. Surg., August 1, 2006; 132(2): 283 - 290.e3.
[Full Text] [PDF]


Home page
PerfusionHome page
J. M van den Goor, W. van Oeveren, P. M Rutten, J. G Tijssen, and L. Eijsman
Adhesion of thrombotic components to the surface of a clinically used oxygenator is not affected by Trillium coating
Perfusion, May 1, 2006; 21(3): 165 - 172.
[Abstract] [PDF]


Home page
PerfusionHome page
S. Gunaydin
Clinical significance of coated extracorporeal circuits: a review of novel technologies
Perfusion, January 1, 2004; 19(1_suppl): S33 - S41.
[Abstract] [PDF]


Home page
PerfusionHome page
C. Baufreton, J. L. de Brux, P. Binuani, J.-J. Corbeau, J. B. Subayi, J. C. Daniel, and P. Treanor
A combined approach for improving cardiopulmonary bypass in coronary artery surgery: a pilot study
Perfusion, December 1, 2002; 17(6): 407 - 413.
[Abstract] [PDF]


Home page
PerfusionHome page
J A Murphy, C M Savage, S K Alpard, D J Deyo, J B Jayroe, and J B Zwischenberger
Low-dose versus high-dose heparinization during arteriovenous carbon dioxide removal
Perfusion, December 1, 2001; 16(6): 460 - 468.
[Abstract] [PDF]


Home page
PerfusionHome page
D. F Larson, D. Arzouman, L. Kleinert, V. Patula, and S. Williams
Comparison of Sarns 3M heparin bonded to Duraflo II and control circuits in a porcine model: macro- and microanalysis of thrombi accumulation in circuit arterial filters
Perfusion, January 1, 2000; 15(1): 13 - 20.
[Abstract] [PDF]