Advanced Search

Journal Navigation

Journal Home

Subscriptions

Archive

Contact Us

Table of Contents

Sign In to gain access to subscriptions and/or personal tools.
Perfusion
This Article
Right arrow Full Text (PDF)
Right arrow References
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Saved Citations
Right arrow Download to citation manager
Right arrowRequest Permissions
Right arrow Request Reprints
Right arrow Add to My Marked Citations
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Right arrow Citing Articles via Scopus
Google Scholar
Right arrow Articles by De Somer, F
Right arrow Articles by Van Nooten, G
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by De Somer, F
Right arrow Articles by Van Nooten, G
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati   Add to Twitter  
What's this?

Can an oxygenator design potentially contribute to air embolism in cardiopulmonary bypass? A novel method for the determination of the air removal capabilities of neonatal membrane oxygenators

F De Somer

Institute of Biomedical Technology, University of Gent

P Dierickx

Institute of Biomedical Technology, University of Gent

D Dujardin

Department of Cardiac Surgery, Division of Perfusion, University Hospital Gent

P Verdonck

Institute Biomedical Technology, University of Gent, Gent

G Van Nooten

Institute Biomedical Technology, University of Gent, Gent

At present, air handling of a membrane oxygenator is generally studied by using an ultrasonic sound bubble counter. However, this is not a quantitative method and it does not give any information on where air was entrapped in the oxygenator and if it eventually was removed through the membrane for gas exchange. The study presented here gives a novel technique for the determination of the air-handling characteristics of a membrane oxygenator. The study aimed at defining not only the amount of air released by the oxygenator, but also the amount of air trapped within the oxygenator and/or removed through the gas exchange membrane. Two neonatal membrane oxygenators without the use of an arterial filter were investigated: the Polystan Microsafe and the Dideco Lilliput. Although the air trap function of both oxygenators when challenged with a bolus of air was similar, the Microsafe obtained this effect mainly by capturing the air in the heat exchanger compartment while the Lilliput did remove a large amount of air through the membrane. In conclusion, the difference in trap function was most striking during continuous infusion of air. Immediate contact with a microporous membrane, avoidance of high velocities within the oxygenator, pressure drop, transit time and construction of the fibre mat all contribute to the air-handling characteristics of a membrane oxygenator.

Perfusion, Vol. 13, No. 3, 157-163 (1998)
DOI: 10.1177/026765919801300302


Add to CiteULike CiteULike   Add to Complore Complore   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati   Add to Twitter Twitter    What's this?


This article has been cited by other articles:


Home page
PerfusionHome page
R. A Rodriguez and D. Belway
Comparison of two different extracorporeal circuits on cerebral embolization during cardiopulmonary bypass in children
Perfusion, September 1, 2006; 21(5): 247 - 253.
[Abstract] [PDF]


Home page
PerfusionHome page
M. Kurusz and B. D Butler
Bubbles and bypass: an update
Perfusion, January 1, 2004; 19(1_suppl): S49 - S55.
[Abstract] [PDF]


Home page
J. Thorac. Cardiovasc. Surg.Home page
A. LaPietra, E. A. Grossi, B. B. Pua, R. A. Esposito, A. C. Galloway, C. C. Derivaux, L. R. Glassman, A. T. Culliford, G. H. Ribakove, and S. B. Colvin
Assisted venous drainage presents the risk of undetected air microembolism
J. Thorac. Cardiovasc. Surg., November 1, 2000; 120(5): 856 - 863.
[Abstract] [Full Text] [PDF]


Home page
PerfusionHome page
J Horisberger, D Jegger, Y Boone, I Seigneul, N Pierrel, M Hurni, A F Corno, and L K von Segesser
Impact of a remote pump head on neonatal priming volumes
Perfusion, September 1, 1999; 14(5): 351 - 356.
[Abstract] [PDF]