Advanced Search

Journal Navigation

Journal Home

Subscriptions

Archive

Contact Us

Table of Contents

Click here to sign up for SAGE Journal Email Alerts today!

Sign In to gain access to subscriptions and/or personal tools.
Perfusion
This Article
Right arrow Full Text (PDF)
Right arrow References
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Saved Citations
Right arrow Download to citation manager
Right arrowRequest Permissions
Right arrow Request Reprints
Right arrow Add to My Marked Citations
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Right arrow Citing Articles via Scopus
Google Scholar
Right arrow Articles by Visser, C
Right arrow Articles by de Jong, D S
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Visser, C
Right arrow Articles by de Jong, D S
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati  
What's this?

Clinical evaluation of six hollow-fibre membrane oxygenators

C Visser

Department of Extracorporeal Circulation, University Hospital Maastricht

D S de Jong

Department of Extracorporeal Circulation, University Hospital Maastricht

In a clinical evaluation to study the performance of hollow-fibre membrane oxygenators, we compared the gas exchange characteristics and the production of plasma free haemoglobin for different oxygenators. In this study, the data of the Univox, Cobe-Optima, Capiox-SX, Affinity, Safe II and Sarns Turbo 440 oxygenators were evaluated during cardiac surgery in comparable patient groups. Thirteen patients scheduled for elective surgery were enrolled in each group. In all groups, cardiopulmonary bypass (CPB) was conducted using pulsatile blood flow during fibrillation and the period in which the aorta was crossclamped. Arterial and venous blood gases were determined from which oxygen transfer, carbon dioxide transfer, oxygen gradient, shunt fraction and diffusing capacity were calculated. Blood samples were taken 5, 30, 60 and 90 min after beginning CPB. As a result of our measurements we found that the gas exchange capacities of all six oxygenators are within clinically acceptable limits, although the data considering oxygen and carbon dioxide transfer showed a significantly higher capacity for the Sarns Turbo 440 oxygenator (p < 0.05) in comparison with the other oxygenators. Plasma free haemoglobin was, however, significantly higher in the Univox and Sarns Turbo 440 groups (p < 0.005). This difference was already present after 30 min of bypass and increased with time, and is considered as a negative aspect, in relation to optimal patient care.

Perfusion, Vol. 12, No. 6, 357-368 (1997)
DOI: 10.1177/026765919701200604


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati    What's this?


This article has been cited by other articles:


Home page
J. Appl. Physiol.Home page
C. Borland, H. Dunningham, F. Bottrill, and A. Vuylsteke
Can a membrane oxygenator be a model for lung NO and CO transfer?
J Appl Physiol, May 1, 2006; 100(5): 1527 - 1538.
[Abstract] [Full Text] [PDF]


Home page
PerfusionHome page
P A. Segers, J F Heida, I de Vries, C Maas, A J Boogaart, and S Eilander
Clinical evaluation of nine hollow-fibre membrane oxygenators
Perfusion, March 1, 2001; 16(2): 95 - 106.
[Abstract] [PDF]