Advanced Search

Journal Navigation

Journal Home

Subscriptions

Archive

Contact Us

Table of Contents

Sign In to gain access to subscriptions and/or personal tools.
Perfusion
This Article
Right arrow Full Text (PDF)
Right arrow References
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Saved Citations
Right arrow Download to citation manager
Right arrowRequest Permissions
Right arrow Request Reprints
Right arrow Add to My Marked Citations
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Right arrow Citing Articles via Scopus
Google Scholar
Right arrow Articles by Mitchell, S.
Right arrow Articles by Gorman, D.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Mitchell, S.
Right arrow Articles by Gorman, D.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati  
What's this?

Emboli generation by the Medtronic Maxima hard shell adult venous reservoir in cardiopulmonary bypass circuits: a preliminary report

SJ Mitchell

Royal New Zealand Naval Hospital, Auckland

T. Willcox

Department of Clinical Perfusion, Greenlane Hospital, Auckland

C. McDougal

Department of Clinical Perfusion, Greenlane Hospital, Auckland

DF Gorman

Royal New Zealand Naval Hospital and School of Medicine, University of Auckland, Auckland

Increases in right common carotid artery Doppler ultrasound signals typical of emboli were found in cardiopulmonary bypass patients when the Medtronic Maxima hard-shell adult combined venous and cardiotomy reservoir was operated at reservoir blood volumes near the manufacturer;s recommended minimum of 300 ml. The signals were reduced by increasing the reservoir blood volume. Possible microembolus generation in the top- and bottom-entry versions of this reservoir was investigated using an in vitro circuit and a colour flow Doppler monitor that was interfaced with a microprocessor to count the signals. The reservoir blood volume was progressively lowered in 100 ml increments below 1000 ml, and signals were counted over five minutes at each new level. Signal counts downstream of the reservoir increased exponentially after the volume was decreased below 1000 ml in the bottom-entry version, and 700 ml in the top-entry version. Ultrasonic monitor ing, both upstream and downstream of the reservoir, showed that the source of these signals was the reservoir itself, and that recirculation of emboli around the circuit accounted for only a small proportion of the measured increase. Changes in circuit blood prime haematocrit within the range 0.11-0.31 did not alter the signal counts. However, counts were profoundly affected by exposure of the circuit to nitrous oxide via a membrane oxygena tor ; this showed that the emboli were bubbles. Bubble formation may occur where venous blood enters the reservoir as this results in a fountaining effect when the reservoir volume is low. This effect appears to have been serendipi tously reduced, but not eliminated, in the design of the top-entry version. It is

Perfusion, Vol. 11, No. 2, 145-155 (1996)
DOI: 10.1177/026765919601100208


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati    What's this?


This article has been cited by other articles:


Home page
PerfusionHome page
P. Nielsen, J. Funder, M. Jensen, and H Nygaard
Influence of venous reservoir level on microbubbles in cardiopulmonary bypass
Perfusion, November 1, 2008; 23(6): 347 - 353.
[Abstract] [PDF]


Home page
PerfusionHome page
J. Lynch and J. Riley
Microemboli detection on extracorporeal bypass circuitsa
Perfusion, January 1, 2008; 23(1): 23 - 32.
[Abstract] [PDF]


Home page
PerfusionHome page
R. A Rodriguez and D. Belway
Comparison of two different extracorporeal circuits on cerebral embolization during cardiopulmonary bypass in children
Perfusion, September 1, 2006; 21(5): 247 - 253.
[Abstract] [PDF]


Home page
PerfusionHome page
R. A Rodriguez, K. A Williams, A. Babaev, F. Rubens, and H. J Nathan
Effect of perfusionist technique on cerebral embolization during cardiopulmonary bypass
Perfusion, January 1, 2005; 20(1): 3 - 10.
[Abstract] [PDF]


Home page
SEMIN CARDIOTHORAC VASC ANESTHHome page
S. J. Mitchell, T. Willcox, F. Paget Milsom, and D. F. Gorman
Physical and Pharmacological Neuroprotection in Cardiac Surgery
Seminars in Cardiothoracic and Vascular Anesthesia, July 1, 2000; 4(2): 80 - 85.
[Abstract] [PDF]


Home page
Ann. Thorac. Surg.Home page
T. W. Willcox, S. J. Mitchell, and D. F. Gorman
Venous air in the bypass circuit: a source of arterial line emboli exacerbated by vacuum-assisted drainage
Ann. Thorac. Surg., October 1, 1999; 68(4): 1285 - 1289.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
F. P. Milsom and S. J. Mitchell
A dual-vent left heart deairing technique markedly reduces carotid artery microemboli
Ann. Thorac. Surg., September 1, 1998; 66(3): 785 - 791.
[Abstract] [Full Text] [PDF]


Home page
PerfusionHome page
S J Mitchell, T Willcox, and D F Gorman
Bubble generation and venous air filtration by hard-shell venous reservoirs: a comparative study
Perfusion, September 1, 1997; 12(5): 325 - 333.