Advanced Search

Journal Navigation

Journal Home

Subscriptions

Archive

Contact Us

Table of Contents

Sign In to gain access to subscriptions and/or personal tools.
Perfusion
This Article
Right arrow Full Text (PDF)
Right arrow References
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Saved Citations
Right arrow Download to citation manager
Right arrowRequest Permissions
Right arrow Request Reprints
Right arrow Add to My Marked Citations
Citing Articles
Right arrow Citing Articles via Google Scholar
Right arrow Citing Articles via Scopus
Google Scholar
Right arrow Articles by Qian, K.
Right arrow Articles by Chu, S.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Qian, K.
Right arrow Articles by Chu, S.
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati   Add to Twitter  
What's this?

In vivo testing of a pulsatile implantable impeller pump as a left ventricular assist device used in calves

KX Qian

Department of Surgery, Medical College of Taiwan University, Taipei, Taiwan

SS Wang

Department of Surgery, Medical College of Taiwan University, Taipei, Taiwan

SH Chu

Department of Surgery, Medical College of Taiwan University, Taipei, Taiwan

A pulsatile implantable impeller pump was tested as a left ventricular assist device in five calves. The experiments lasted for 4-11 days. Death or termination was mainly due to respiratory complications or bleeding, irrelevant to the pump itself. As indicators of haemolysis, thrombogenesis, renal and hepatic functions, free haemoglobin( FHb), haematocrit (Hct), platelet number (Plt), lactate dehydrogenase (LDH), blood urea nitrogen (BUN), creatinine, serum glutamic oxalacetic transaminase (GOT) and total bilirubin were measured preoperatively, at the beginning of the pumping (pump on), six hours later and every day thereafter. The data indicated that the pump caused no severe blood damage or organ dysfunction. Thus, the feasibility of a pulsatile centrifugal pump was demonstrated. The pump with its driver weighs 110 g and is capable of delivering a blood flow up to 8 l/min against 100 mmHg mean pressure.

Perfusion, Vol. 10, No. 4, 257-263 (1995)
DOI: 10.1177/026765919501000409


Add to CiteULike CiteULike   Add to Complore Complore   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati   Add to Twitter Twitter    What's this?