Advanced Search

Journal Navigation

Journal Home

Subscriptions

Archive

Contact Us

Table of Contents

Sign In to gain access to subscriptions and/or personal tools.
Perfusion
This Article
Right arrow Full Text (PDF)
Right arrow References
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Alert me to new issues of the journal
Right arrow Add to Saved Citations
Right arrow Download to citation manager
Right arrowRequest Permissions
Right arrow Request Reprints
Right arrow Add to My Marked Citations
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Right arrow Citing Articles via Scopus
Google Scholar
Right arrow Articles by Swain, J. A
Right arrow Search for Related Content
PubMed
Right arrow Articles by Swain, J. A
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati  
What's this?

Reviews

Review article : Acid-base status, hypothermia and cardiac surgery

Julie A Swain

National Heart, Lung and Blood Institute, Bethesda

The optimal method of pH management during hypothermia is controversial. A review of current experimental and laboratory investigations comparing different pH schemes is presented. The biochemical and metabolic consequences of keeping pH constant (pH-stat) as compared to allowing the pH to increase with hypothermia (alpha-stat) are discussed. It is concluded that, on the basis of experimental and clinical studies, the alpha-stat pH management scheme may be preferable to that of keeping pH constant throughout a wide temperature range in humans.

Perfusion, Vol. 1, No. 4, 231-238 (1986)
DOI: 10.1177/026765918600100401


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati    What's this?


This article has been cited by other articles:


Home page
PerfusionHome page
D. W Fried, T. L Zombolas, J. J Leo, H. Mohamed, and G. J Mattioni
Clinical oxygen transfer comparison of the Terumo Capiox SX18 and SX25 membrane oxygenators
Perfusion, March 1, 1998; 13(2): 119 - 127.
[Abstract] [PDF]


Home page
PerfusionHome page
D. W. Fried, B. N. DeBenedetto, J. J. Leo, G. J. Mattioni, H. Mohamed, and T. L. Zombolas
Clinical oxygen transfer performance of the Sorin Monolyth membrane oxygenator
Perfusion, March 1, 1994; 9(2): 119 - 126.
[Abstract] [PDF]


Home page
PerfusionHome page
D. W. Fried and H. Mohamed
Use of the oxygen transfer slope and estimated membrane oxygen transfer to predict PaO2
Perfusion, January 1, 1994; 9(1): 49 - 55.
[Abstract] [PDF]


Home page
PerfusionHome page
D. W Fried, B. N DeBenedetto, T. L Zombolas, and J. J Leo
Clinical evaluation of the Medtronic Maxima Plus membrane oxygenator
Perfusion, January 1, 1994; 9(5): 363 - 372.
[Abstract] [PDF]


Home page
PerfusionHome page
D. W Fried, T. L Zombolas, M. Wilgus, H. Mohamed, and G. Mattioni
Differential diagnosis of suboptimal oxygenator performance
Perfusion, November 1, 1993; 8(6): 483 - 488.
[Abstract] [PDF]


Home page
PerfusionHome page
D. W Fried and J. Bell-Thomson
A comparison of two oxygen transfer strategies: Bentley Univox and the Bard HF 5000
Perfusion, April 1, 1992; 7(2): 141 - 148.
[Abstract] [PDF]


Home page
PerfusionHome page
D. Pearson
Blood gas control during cardiopulmonary bypass
Perfusion, April 1, 1988; 3(2): 113 - 133.
[PDF]


Home page
PerfusionHome page
D. T Pearson, R. Clayton, A. Murray, and B. McArdle
A clinical evaluation of the Bentley 10B and Bentley 10Plus bubble oxygenators
Perfusion, January 1, 1988; 3(1): 55 - 63.
[Abstract] [PDF]