Sign In to gain access to subscriptions and/or personal tools.
|
Review article : Acid-base status, hypothermia and cardiac surgery
Julie A Swain
National Heart, Lung and Blood Institute, Bethesda
The optimal method of pH management during hypothermia is controversial. A review of current experimental and laboratory investigations comparing different pH schemes is presented. The biochemical and metabolic consequences of keeping pH constant (pH-stat) as compared to allowing the pH to increase with hypothermia (alpha-stat) are discussed. It is concluded that, on the basis of experimental and clinical studies, the alpha-stat pH management scheme may be preferable to that of keeping pH constant throughout a wide temperature range in humans.
Perfusion, Vol. 1, No. 4,
231-238 (1986)
DOI: 10.1177/026765918600100401

CiteULike Connotea Del.icio.us Digg Reddit Technorati What's this?
This article has been cited by other articles:

|
 |

|
 |
 
D. W Fried, T. L Zombolas, J. J Leo, H. Mohamed, and G. J Mattioni
Clinical oxygen transfer comparison of the Terumo Capiox SX18 and SX25 membrane oxygenators
Perfusion,
March 1, 1998;
13(2):
119 - 127.
[Abstract]
[PDF]
|
 |
|

|
 |

|
 |
 
D. W. Fried, B. N. DeBenedetto, J. J. Leo, G. J. Mattioni, H. Mohamed, and T. L. Zombolas
Clinical oxygen transfer performance of the Sorin Monolyth membrane oxygenator
Perfusion,
March 1, 1994;
9(2):
119 - 126.
[Abstract]
[PDF]
|
 |
|

|
 |

|
 |
 
D. W. Fried and H. Mohamed
Use of the oxygen transfer slope and estimated membrane oxygen transfer to predict PaO2
Perfusion,
January 1, 1994;
9(1):
49 - 55.
[Abstract]
[PDF]
|
 |
|

|
 |

|
 |
 
D. W Fried, B. N DeBenedetto, T. L Zombolas, and J. J Leo
Clinical evaluation of the Medtronic Maxima Plus membrane oxygenator
Perfusion,
January 1, 1994;
9(5):
363 - 372.
[Abstract]
[PDF]
|
 |
|

|
 |

|
 |
 
D. W Fried, T. L Zombolas, M. Wilgus, H. Mohamed, and G. Mattioni
Differential diagnosis of suboptimal oxygenator performance
Perfusion,
November 1, 1993;
8(6):
483 - 488.
[Abstract]
[PDF]
|
 |
|

|
 |

|
 |
 
D. W Fried and J. Bell-Thomson
A comparison of two oxygen transfer strategies: Bentley Univox and the Bard HF 5000
Perfusion,
April 1, 1992;
7(2):
141 - 148.
[Abstract]
[PDF]
|
 |
|

|
 |

|
 |
 
D. Pearson
Blood gas control during cardiopulmonary bypass
Perfusion,
April 1, 1988;
3(2):
113 - 133.
[PDF]
|
 |
|

|
 |

|
 |
 
D. T Pearson, R. Clayton, A. Murray, and B. McArdle
A clinical evaluation of the Bentley 10B and Bentley 10Plus bubble oxygenators
Perfusion,
January 1, 1988;
3(1):
55 - 63.
[Abstract]
[PDF]
|
 |
|
|
|